Sign In | Join Free | My udpf.com |
|
Place of Origin : Guangdong, China
Brand Name : SUCE
Model Number : IS50
Packaging Details : standard package
Supply Ability : 5000 Set/Sets per Month
Price : $499.00 - $599.00/Sets
Certification : CE,ISO13485
MOQ : 1PC
Payment Terms : T/T, Western Union,Payoneer
Delivery Time : about 5 days
Power Source : Electricity, AC 100V~240V, 50/60Hz
Warranty : 1 Year
After-sale Service : Onsite Training
Material : Plastic
Shelf Life : 1years
Quality Certification : ce
Instrument classification : Class II
Safety standard : GB/T18830-2009
Product name : Double channel Syringe Pump
Special function : With drug library
Volume Limit : 0.1ml~9999.9ml
Flow Rate Accuracy : Within ±3% (after correct calibration)
Mechanical precision : Within ±2%
Total Injection Volume : 0.1ml~9999.9ml (0.1ml step)
KVO rate : 1ml/h
Fuse : F1AL/250/60V, 2pcs inside
IP Classification : IPX4
Port : guangzhou
Automated single channel Double channel infusion pump tci standard with drug library IS50
Special function | With drug library |
Rate: | 50/60ml Syringe: 0.1ml/h~999.9ml/h (0.1ml/h step) 1,000ml/h~1,500ml/h (1ml/h step) 30ml Syringe: 0.1ml/h~900.0ml/h (0.1ml/h step) 20ml Syringe: 0.1ml/h~600.0ml/h (0.1ml/h step) 10ml Syringe: 0.1ml/h~300.0ml/h (0.1ml/h step) |
Flow Rate Accuracy: | Within ±3% (after correct calibration) |
Mechanical precision: | Within ±2% |
Bolus Rate: | 50/60ml Syringe: 1,200ml/h 30 ml Syringe: 720ml/h 20 ml Syringe: 480ml/h 10 ml Syringe: 240ml/h |
Purge Rate: | 50/60ml Syringe: 1,500ml/h 30ml Syringe: 900ml/h 20ml Syringe: 600ml/h 10ml Syringe: 300ml/h |
Volume Limit: | 0.1ml~999.9ml |
Total Injection Volume: | 0.1ml~9999.9ml (0.1ml step) |
Occlusion: | High: 800mmHg ±200mmHg (106.7kPa±26.7kPa Medium: 50/600mmHg ±100mmHg (66.7kPa±13.3kPa Low: 300mmHg ±100mmHg (40.7kPa±13.3kPa ) |
Alarms: | Injection soon finish, end of injection,occlusion, improperly installation of syringe, wrong setting, low battery, syringe loose etc. |
Power Source: | AC 100V~240V, 50/60Hz; Internal rechargeable Li battery, capacity≥1,600mAh, 4 hours internal battery backup |
KVO rate: | 1ml/h |
Fuse: | F1AL/250/60V, 2pcs inside |
Power Consumption: | 30VA |
IP Classification: | IPX1 |
Equipment Classification: | Class II, internal power supply, Type BF |
Operating Condition: | Ambient temperature: +5℃~+40℃; |
Relative humidity: | 20~90% |
Transport & Storage Condition: | Ambient temperature: -30℃~+55℃ |
Relative humidity: | ≤95% |
Dimension: | 280mm (L) × 210mm (W) × 130mm (H) |
Weight: | 2.2kg (net weight) |
Drug Library.
Separate operation between the two single channels.
Three working modes: rate mode, time-volume mode, dosage-weight mode.
Automatically calibration and compatible with all standard syringes of 10ml~50ml..
Freely Stackable: Users can freely stack one syringe pump onto another to provide multiple Solutions, which have a wide range of
clinical applications.
Large LCD screen displays working status.
KVO and Bolus functions.
Save the last infusion rate automatically when there is unpredicatable switch off.
Transfer the message between the Nurse-call System and the pumps.
![]() |
Automated Single Channel Dual Channel Infusion Pump Tci Standard Images |